S5 Upconversion Data Quality Flags

  • The flags are placed at the time period that the interferometer was possibly affected by the upconversion by observing the scaled H1:SUS-ETMY_COIL_LL signal. A threshold was applied to the scaled COIL_LL for 1% dead time
  • The scaled H1:SUS-ETMY_COIL_LL was generated by applying a scaling function on the COIL_LL signal. The function equalize the contribution of the COIL_LL to the upconversion noise in 70-110Hz H1:DARM_ERR.
  • The scaling functioin was produced from the estimation of the contribution of each peak of the COIL_LL power spectrum to the H1:DARM_ERR.
List of the upconversion data quality flags (start, stop, duration)

H1:SUS-ETMY_COIL_LL Power Spectrum

Scaling Function

  • Gray Line: S5 Scaling function generated based on the test segments (See this link for the test segments).
  • Gray X symbol: Reference scaling factor based on the test segment.
  • Each Dot represents a slope of a linear fit curve for the DARM_ERR 70-110Hz vs COIL_LL BLRMS. The COIL_LL BLRMS is in one of six frequency bands (0.1-0.3,1.0-1.6,1.8-2.6,5.0-7.0, 10.0-13.0 and 17.0-19.0Hz). The dots calculated every 3.5 days for a week of data. See the bottom of this link how the slopes (dots) were calculated.
  • The following equation shows how the scaling function is applied to the COIL_LL.
    (f: frequency, Pw: power after scaled, w: scaling factor at f, P: coil power at f)
S5 Second Year Scaling Function (RMS^2)
S5 Second Year Scaling Function (RMS)
S5 Second Year (No Scale, RMS^2)
S5 Second Year (No Scale, RMS)
S5 Second Year (Scaled, RMS^2)
S5 Second Year (Scaled, RMS)
S5 Second Year Amplitude (RMS^2)
S5 Second Year Amplitude (RMS)

Overlap with SIDECOIL DQ and SEISMIC_EY_99PCTL flags for S5 2nd Year

DQ Flag Name Total Time (Sec) Overlapped Time (Sec) # Total DQ Segments # Overlapped Segments
SIDECOIL_ETMX 32089 138 (0.4301%) 9425 71
SIDECOIL_ETMY 100404 42 (0.04183%) 30738 24
SIDECOIL_ETMX_RMS_6HZ 766 277 (36.16%) 106 37
SIDECOIL_ETMY_RMS_6HZ 13518 133 (0.9987%) 2101 22
SEISMIC_EY_99PCTL_3_10HZ 275580 4468 (1.621%) 3641 103
* Overlapped segments include partially overlapped segments.

BLRMS Timeseries and Flagged segments

  • Top: H1:DARM_ERR timeseries for 70-110Hz
  • Middle: H1:EMTY_COIL_LL timeseries for 0.1-40Hz
  • Bottom: Scaled H1:EMTY_COIL_LL timeseries for 0.1-40Hz
  • Gray Line: Threshold for 1% dead time (3.056e-13)